Evaluation of QRS dispersion and its association with tachyarrhythmia events in patients with implanted cardiac resynchronization therapy defibrillator device

Evaluation of QRS dispersion and its association with tachyarrhythmia events in patients with implanted cardiac resynchronization therapy defibrillator device


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: فریبرز اکبرزاده , بابک کاظمی اربط , الگار انعام زاده , بهناز قمری , فرید کارکن شایان

کلمات کلیدی: Arrhythmia, Cardiac Resynchronization Therapy Defibrillator, QRS dispersion

نشریه: 0 , 1 , 6 , 2018

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله فریبرز اکبرزاده
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات قلب وعروق
کد مقاله 64238
عنوان فارسی مقاله Evaluation of QRS dispersion and its association with tachyarrhythmia events in patients with implanted cardiac resynchronization therapy defibrillator device
عنوان لاتین مقاله Evaluation of QRS dispersion and its association with tachyarrhythmia events in patients with implanted cardiac resynchronization therapy defibrillator device
ناشر 6
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق) journal of analytical research in clinical medicine
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح چهار – SID/Iranmedex/Magiran
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Abstarct: Introduction: Heart failure (HF) is one of the major problems of health system in the countries. In a subgroup of these patients, cardiac resynchronization therapy defibrillator (CRT-D) improves the quality of life by enhancing the function of the left ventricle (LV) and preventing of arrhythmias. The present study intends to discuss the effect of CRT-D on the QRS dispersion, as a predisposing factor to arrhythmias. Methods: 45 patients treated with CRT-D during 2012-2015 were enrolled in this study. QRS dispersion in various V-V delays was measured and its association with the incidence of arrhythmias, at least six months after insertion, was assessed. Results: The results showed that QRS dispersion in the intrinsic mode was significantly lower than the other modes of the CRT-D device (P < 0.001). Besides, it was revealed that mean QRS duration in the intrinsic mode had a higher association with arrhythmic events than max QRS duration. Conclussion: QRS dispersion after CRT-D implantation had a significant increase compared to the intrinsic mode. However, it did not correlate with the arithmetic events. Further decrease in the duration of QRS after CRT-D implantation improved arrhythmias. QRS dispersion after CRT-D implantation is not an indicative of arrhythmia risk, and a decrease in the duration of QRS had a more significant effect on the incidence of arrhythmias.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
فریبرز اکبرزادهاول
بابک کاظمی اربطدوم
الگار انعام زادهسوم
بهناز قمریپنجم
فرید کارکن شایانششم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Khaki.pdf1397/07/27877340دانلود