Targeting and sensing of some cancer cells using folate bioreceptor functionalized nitrogen-doped graphene quantum dots
Targeting and sensing of some cancer cells using folate bioreceptor functionalized nitrogen-doped graphene quantum dots
نویسندگان: جعفر سلیمانی , محمد حسن زاده محله , ابوالقاسم جویبان , محمد حسین صومی
کلمات کلیدی: Folate bioreceptor, Cell targeting, Cytosensor, Nitrogen doped graphene quantum dots, Cancer diagnosis
نشریه: 15718 , 01 , 118 , 2018
| نویسنده ثبت کننده مقاله |
محمد حسن زاده محله |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
مرکز تحقیقات کاربردی دارویی |
| کد مقاله |
63404 |
| عنوان فارسی مقاله |
Targeting and sensing of some cancer cells using folate bioreceptor functionalized nitrogen-doped graphene quantum dots |
| عنوان لاتین مقاله |
Targeting and sensing of some cancer cells using folate bioreceptor functionalized nitrogen-doped graphene quantum dots |
| ناشر |
5 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
بلی |
| عنوان نشریه (خارج از لیست فوق) |
|
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح یک – ISI - Web of Science |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| In recent years, study of folate receptor (FR) expression related to targeting, drug delivery and counting of tumoral cells have been followed. In this work, a fast and simple strategy was reported to determine the FR expressed cancer cells based on the selective bonding of the folic acid/folate (FA) to the FR-positive tumor cells. The folate decorated Nitrogen-doped graphene quantum dots (N-GQDs) were utilized as selective targeting of the MKN 45 cells. Fluorescent microscopy imaging investigations revealed that the produced FA conjugated N-GQDs could specifically attach to the target FR-positive tumor cells. Due to the fluorescence emission of N-GQDs, the developed cytosensor is free from attaching any fluorescent ligand i.e. Rhodamine B to capture the florescence microscopy images and also flow cytometry analysis. The fabricated cytosensor possesses a dynamic range from 100 to 7.0 × 104 cell·mL−1 with high selectivity. Furthermore, the cytosensor also could visualized the MCF 7 and HT 29 cells where the dynamic ranges were 100 to 1.0 × 104 and 500 to 4.0 × 104 cells·mL−1, respectively. In vitro toxicity tests has shown low toxicity of the synthesized N-GQDs where the minimum viability is 68%. The proposed FA-N-GQDs based cytosensor provides a novel platform for detection of MKN 45, HT 29 and MCF 7 cancer cell lines which could be used in multi-channel cancer diagnosis biodevice. |
| نام فایل |
تاریخ درج فایل |
اندازه فایل |
دانلود |
| 146.pdf | 1397/04/25 | 4463298 | دانلود |