Targeting and sensing of some cancer cells using folate bioreceptor functionalized nitrogen-doped graphene quantum dots

Targeting and sensing of some cancer cells using folate bioreceptor functionalized nitrogen-doped graphene quantum dots


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: جعفر سلیمانی , محمد حسن زاده محله , ابوالقاسم جویبان , محمد حسین صومی

کلمات کلیدی: Folate bioreceptor, Cell targeting, Cytosensor, Nitrogen doped graphene quantum dots, Cancer diagnosis

نشریه: 15718 , 01 , 118 , 2018

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محمد حسن زاده محله
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات کاربردی دارویی
کد مقاله 63404
عنوان فارسی مقاله Targeting and sensing of some cancer cells using folate bioreceptor functionalized nitrogen-doped graphene quantum dots
عنوان لاتین مقاله Targeting and sensing of some cancer cells using folate bioreceptor functionalized nitrogen-doped graphene quantum dots
ناشر 5
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

In recent years, study of folate receptor (FR) expression related to targeting, drug delivery and counting of tumoral cells have been followed. In this work, a fast and simple strategy was reported to determine the FR expressed cancer cells based on the selective bonding of the folic acid/folate (FA) to the FR-positive tumor cells. The folate decorated Nitrogen-doped graphene quantum dots (N-GQDs) were utilized as selective targeting of the MKN 45 cells. Fluorescent microscopy imaging investigations revealed that the produced FA conjugated N-GQDs could specifically attach to the target FR-positive tumor cells. Due to the fluorescence emission of N-GQDs, the developed cytosensor is free from attaching any fluorescent ligand i.e. Rhodamine B to capture the florescence microscopy images and also flow cytometry analysis. The fabricated cytosensor possesses a dynamic range from 100 to 7.0 × 104 cell·mL−1 with high selectivity. Furthermore, the cytosensor also could visualized the MCF 7 and HT 29 cells where the dynamic ranges were 100 to 1.0 × 104 and 500 to 4.0 × 104 cells·mL−1, respectively. In vitro toxicity tests has shown low toxicity of the synthesized N-GQDs where the minimum viability is 68%. The proposed FA-N-GQDs based cytosensor provides a novel platform for detection of MKN 45, HT 29 and MCF 7 cancer cell lines which could be used in multi-channel cancer diagnosis biodevice.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
جعفر سلیمانیاول
محمد حسن زاده محلهدوم
ابوالقاسم جویبانپنجم
محمد حسین صومیسوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
146.pdf1397/04/254463298دانلود