The effect of different coating materials on the prevention of powder bounce in the next generation impactor

The effect of different coating materials on the prevention of powder bounce in the next generation impactor


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: شادی فرشباف , علی نخودچی , حامد همیشه کار

کلمات کلیدی: Metered dose inhalers; Next generation impactor; Coating; Bounce

نشریه: 29469 , 3 , 13 , 2018

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله حامد همیشه کار
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات کاربردی دارویی
کد مقاله 62911
عنوان فارسی مقاله The effect of different coating materials on the prevention of powder bounce in the next generation impactor
عنوان لاتین مقاله The effect of different coating materials on the prevention of powder bounce in the next generation impactor
ناشر 4
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Short Communication
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

In the process of quality control of pulmonary drug delivery products, aerosolization efficiency is mainly determined using impactors, e.g. next generation impactor (NGI). However, particle bounce may interfere with the validity and accuracy of results due to the overestimation of the respirable fraction. It is suggested that the coating of impactor’s stages may prevent the particle bounce. Therefore, coating materials may influence the results of the aerosolization indexes of pulmonary dosage forms. The aim of this study was to investigate if the aerosolization indices are affected differently by using the different coating materials. In this study, the effects of using different materials including Span® 85, Tween® 80, silicon® oil, glycerin and Brij® 35/glycerin mixture recommended for the coating of NGI stages on the aerosolization indices such as fine particle fraction, fine particle dose, mass median aerodynamic diameter, and geometric standard deviation of salbutamol emitted from a commercial metered dose inhaler (MDI), were assessed. Three statistically different results were obtained on using Tween® 80, Span® 85 and silicon oil, and glycerin and Brij®35/glycerin mixture. It can be concluded that the type of coating material influenced the aerosolization indices of the examined MDI in NGIs.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
شادی فرشبافاول
علی نخودچیسوم
حامد همیشه کارچهارم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
2018-Farshbaf-RPS.pdf1397/02/22372185دانلود