A comparative study of the disinfection efficacy of H2O2/ferrate and UV/ H2O2/ferrate processes on inactivation of Bacillus subtilis spores by response surface methodology for modeling and optimization

A comparative study of the disinfection efficacy of H2O2/ferrate and UV/ H2O2/ferrate processes on inactivation of Bacillus subtilis spores by response surface methodology for modeling and optimization


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: حسن اصلانی

کلمات کلیدی: Disinfection Bacillus subtilis spores UV radiation/ H2O2 /ferrate Response surface methodology (RSM) Central composite design (CCD)

نشریه: 55171 , 2018 , 116 , 2018

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله حسن اصلانی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده بهداشت
کد مقاله 62793
عنوان فارسی مقاله A comparative study of the disinfection efficacy of H2O2/ferrate and UV/ H2O2/ferrate processes on inactivation of Bacillus subtilis spores by response surface methodology for modeling and optimization
عنوان لاتین مقاله A comparative study of the disinfection efficacy of H2O2/ferrate and UV/ H2O2/ferrate processes on inactivation of Bacillus subtilis spores by response surface methodology for modeling and optimization
ناشر 7
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Although chlorination can inactivate most of the microorganisms in water but protozoan parasites like C. parvum oocysts and Giardia cysts can resist against it. Therefore, many researches have been conducted to find a novel method for water disinfection. Present study evaluated the synergistic effect of H2O2 and ferrate followed by UV radiation to inactivate Bacillus subtilis spores as surrogate microorganisms. Response surface methodology(RSM) was employed for the optimization for UV/H2O2/ferrate and H2O2/ferrate processes. By using central composite design(CCD), the effect of three main parameters including time, hydrogen peroxide, and ferrate concentrations was examined on process performance. The results showed that the combination of UV, H2O2 and ferrate was the most effective disinfection process in compare with when H2O2 and ferrate were used. This study indicated that by UV/H2O2/ferrate, about 5.2 log reductions of B. subtilis spores was inactivated at 9299 mg/l of H2O2 and 0.4 mg/l of ferrate concentrations after 57 min of contact time which was the optimum condition, but H2O2/ferrate can inactivate B. subtilis spores about 4.7 logs compare to the other process. Therefore, the results of this research demonstrated that UV/H2O2 /ferrate process is a promising process for spore inactivation and water disinfection.