Effect of combined application of high- and low-intensity lasers on dentin hypersensitivity: A randomized clinical trial

Effect of combined application of high- and low-intensity lasers on dentin hypersensitivity: A randomized clinical trial


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: مرتضی قوجازاده , زهرا خلیلی صدرآباد

کلمات کلیدی: Diode laser, dentin hypersensitivity, desensitizing effect

نشریه: 19913 , 1 , 12 , 2018

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله زهرا خلیلی صدرآباد
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 62605
عنوان فارسی مقاله Effect of combined application of high- and low-intensity lasers on dentin hypersensitivity: A randomized clinical trial
عنوان لاتین مقاله Effect of combined application of high- and low-intensity lasers on dentin hypersensitivity: A randomized clinical trial
ناشر 6
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Abstract Background. Diode lasers (DLs) have demonstrated equal or better desensitizing effects than fluoride varnish, 10% potassium nitrate (NK) gel and Gluma. The current study evaluated the desensitizing effect of combined application of DLs with two different output powers and compared it with single DL therapy. Methods. Sixty-two hypersensitive teeth were allocated randomly into two groups: the single group was treated with 3-W DL beam once and in the combined group, the teeth were irradiated three times (the first time with 0.2-W and then with 3-W and the second and third times, 48 and 96 hours after the baseline visit, with 0.2-W DL beams). The amount of dentin hypersensitivity (DH) was evaluated, immediately before and after each visit, and 1 week and 1 and 3 months after the first visit. Data analysis was performed using chi-squared test, repeated measurement of ANOVA and Mann-Whitney U test. P<0.05 was considered statistically significant. Results. Statistically significant changes were observed in the means of VAS indices between all the measurement intervals and pretreatment measures, in both experimental groups (P<0.001). The difference in VAS reduction among the groups was not significant when the hypersensitive teeth were stimulated by a periodontal probe and a jet of air (P=0.63 and P=0.12). Conclusion. The results of the present study showed that using both high-intensity and combined DL beams gives rise to significant reductions in DH. There was no significant difference between combined and single laser therapies in the treatment of tooth hypersensitivity.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
مرتضی قوجازادهششم
زهرا خلیلی صدرآبادپنجم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
joddd-12-49.pdf1397/01/15563493دانلود