Evaluation of an Immunomodulator Drug as a Radioprotectant on Human Peripheral Blood Lymphocytes In Vitro

Evaluation of an Immunomodulator Drug as a Radioprotectant on Human Peripheral Blood Lymphocytes In Vitro


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: بهزاد برادران , علیرضا فرج الهی , محمد اصغری جعفرآبادی , وحید خاضع شاهگلی , جلیل پیرایش اسلامیان

کلمات کلیدی: Immunomodulator drug (IMOD™), Radioprotectant, Lymphocyte, Micronuclei assay, Apoptosis

نشریه: 24125 , 1 , 9 , 2018

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله جلیل پیرایش اسلامیان
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده پزشکی
کد مقاله 62104
عنوان فارسی مقاله Evaluation of an Immunomodulator Drug as a Radioprotectant on Human Peripheral Blood Lymphocytes In Vitro
عنوان لاتین مقاله Evaluation of an Immunomodulator Drug as a Radioprotectant on Human Peripheral Blood Lymphocytes In Vitro
ناشر 6
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت http://mejc.sums.ac.ir/index.php/mejc/article/view/631

خلاصه مقاله
hide/show

Background: IMOD™, a selenium enriched extract of the plants Tanacetum vulgare, Urtica dioica, and Rosa canina, has an excellent effect on oxidative stress. In this study, we investigated the radioprotective effects of this immunomodulatory drug on human peripheral blood lymphocytes. Methods: Peripheral blood samples obtained from venipuncture of the brachial vein were treated with IMOD™ (5, 10, 15, 20 μl) for 30 min and Cobalt 60 γ-rays (0.25, 0.5, 1, 2 Gy) as the test groups and cultured with the control. We used the micronuclei assay, cell death detection, and cell toxicity assay to analyze the treatment effects. Results: The frequency of micronuclei were 1.66 (0 Gy), 5.33 (0.25 Gy), 9.67 (0.5 Gy), 17.67 (1 Gy), and 23.67 (2 Gy) in the irradiated lymphocytes (P<0.001). The percentage of micronuclei frequency reduced to 20%, 26.83%, 37.68%, 16%, and 20.47% with IMOD™. Apoptosis and necrosis decreased significantly in the IMOD™ treated groups (P<0.05). Conclusion: IMOD™ may protect these cells against ionizing radiation.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
بهزاد برادراندوم
علیرضا فرج الهیسوم
محمد اصغری جعفرآبادیچهارم
وحید خاضع شاهگلیپنجم
جلیل پیرایش اسلامیانششم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Evaluation of an Immunomodulator Drug as a Radioprotectant on Human Peripheral Blood Lymphocytes In Vitro.pdf1396/10/20820820دانلود