Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation

Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: فرزاد رحمانی , حسن سلیمانپور , عطا محمودپور , کاووس شهسواری نیا , جعفر رحیمی پناهی , سروین سنایی اسکویی , مریم سلیمان پور , رباب مهدیزاده

کلمات کلیدی: Endotracheal Intubation Tracheal Tube Cuff Pressure Emergency Department

نشریه: 0 , 9 , 4 , 2017

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله حسن سلیمانپور
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز مدیریت و پیشگیری از مصدومیتهای حوادث ترافیکی
کد مقاله 62083
عنوان فارسی مقاله Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation
عنوان لاتین مقاله Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation
ناشر 9
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق) Journal of Cardiovascular and Thoracic Research
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت http://jcvtr.tbzmed.ac.ir/PDF/jcvtr-9-169.pdf?t=636508241853208808

خلاصه مقاله
hide/show

Introduction: Filling tracheal tube cuff (TTC) after intubation is necessary to provide a safe airway in intubated patients. On the other hand, excessive increase or decrease in the pressure of TTC’s balloon leads into the dangerous complications such as necrosis and/or aspiration. Accordingly, in the present study, we tried to evaluate the most two common fixed volume and pilot balloon palpitation methods to control TTC pressure. Methods: In a prospective cross-sectional study that was carried out in the emergency department of Tabriz Imam Reza hospital upon 194 patients who needed intubation and from April 2015 to June 2016. The patients were randomly allocated into two equal groups. For the first the Pilot Balloon Palpation technique and for the second group 10 cc fixed volume cuff filling technique was assigned. After that, the pressure was checked with manometer and data were analyzed using SPSS software. Results: TTC pressure average in fixed volume group was 44.96±21.77 cmH2O and for palpation group, it was 118.15±22.15 cmH2O. There was a meaningful difference between two groups in terms of cuff inside pressure (P value <0.001) and it was meaningfully lower in fixed volume group than the first one. Conclusion: The present study showed that pilot balloon palpation or fixed volume method was not appropriate methods to assess cuff pressure during intubation and the cuff pressure must be controlled by the manometer.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
فرزاد رحمانیاول
حسن سلیمانپوردوم
عطا محمودپورچهارم
کاووس شهسواری نیاپنجم
جعفر رحیمی پناهیششم
سروین سنایی اسکوییهفتم
مریم سلیمان پورهشتم
رباب مهدیزادهنهم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
jcvtr-9-169.pdf1396/10/16401935دانلود