Factors affecting marginal integrity of class II bulk-fill composite resin restorations.

Factors affecting marginal integrity of class II bulk-fill composite resin restorations.


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: سیاوش سوادی اسکویی , محمود بهاری , المیرا جعفری نویمی پور , امیر احمد عجمی

کلمات کلیدی: Composite resin; bulk fill; curing light; marginal gap; methacrylate; silorane

نشریه: 42257 , 2 , 11 , 2017

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محمود بهاری
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات لثه و دندان
کد مقاله 61422
عنوان فارسی مقاله Factors affecting marginal integrity of class II bulk-fill composite resin restorations.
عنوان لاتین مقاله Factors affecting marginal integrity of class II bulk-fill composite resin restorations.
ناشر 6
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5519990/pdf/joddd-11-101.pdf

خلاصه مقاله
hide/show

Background. Bulk-fill composite resins are a new type of resin-based composite resins, claimed to have the capacity to be placed in thick layers, up to 4 mm. This study was carried out to evaluate factors affecting gap formation in Cl II cavities restored using the bulk-fill technique. Methods. A total of 60 third molars were used in this study. Two Cl II cavities were prepared in each tooth, one on the mesial aspect 1 mm coronal to the CEJ and one on the distal aspect 1 mm apical to the CEJ. The teeth were divided into 4 groups: A: The cavities were restored using the bulk-fill technique with Filtek P90 composite resin and its adhesive system and light-cured with quartz tungsten halogen (QTH) light-curing unit. B: The cavities were restored similar to that in group A but light-cured with an LED light-curing unit. C: The cavities were restored using the bulk-fill technique with X-tra Fil composite resin and Clearfil SE Bond adhesive system and light-cured with a QTH curing unit. D: The cavities were restored similar to that in group C but light-cured with an LED light-curing unit. The gaps were examined under a stereomicroscope at ×60. Data were analyzed with General Linear Model test. In cases of statistical significance (P<0.05), post hoc Bonferroni test was used for further analyses. Results. The light-curing unit type had no effect on gap formation. However, the results were significant in relation to the composite resin type and margin location (P<0.001). The cumulative effects of light-curing unit*gingival margin and light-curing unit*composite resin type were not significant; however, the cumulative effect of composite rein type*gingival margin was significant (P=0.04) Conclusion. X-tra Fil composite exhibited smaller gaps compared with Filtek P90 composite with both light-curing units. Both composite resins exhibited smaller gaps at enamel margins.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
سیاوش سوادی اسکوییاول
محمود بهاریدوم
المیرا جعفری نویمی پورسوم
امیر احمد عجمیچهارم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
joddd-11-101.pdf1396/06/28275594دانلود