Evaluation of interdental spaces of mandibular posterior area for orthodontic mini-implants with cone-beam computed tomography

Evaluation of interdental spaces of mandibular posterior area for orthodontic mini-implants with cone-beam computed tomography


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: سید حسین مسلم زاده , آیدین سهرابی , علی رفیقی , امین نوری زاده

کلمات کلیدی: Anchorage preparation; Temporary anchorage devices; Tooth movement

نشریه: 19694 , 4 , 11 , 2017

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله علی رفیقی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 61170
عنوان فارسی مقاله Evaluation of interdental spaces of mandibular posterior area for orthodontic mini-implants with cone-beam computed tomography
عنوان لاتین مقاله Evaluation of interdental spaces of mandibular posterior area for orthodontic mini-implants with cone-beam computed tomography
ناشر 5
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت http://jcdr.net/articles/PDF/9520/25436_CE[Ra1]_F(GH)_PF1(PrG_RK)_PFA(P)_PF2(PGGH).pdf

خلاصه مقاله
hide/show

Abstract INTRODUCTION: The use of mini-implants has increased in recent years because of their role in absolute anchorage, but the placement sites may affect the success or failure of the procedure, so it is very important to determine the appropriate and safe location for orthodontic mini-implants. On the other hand, the Cone Beam Computed Tomography (CBCT), which offers clear 3-Dimentional (3D) images, has been widely used in orthodontics and implant dentistry for surgical guidance of mini-implant placement. AIM: The aim of this retrospective study was to evaluate inter-radicular spaces between mandibular canines to second molars using cone beam 3D images. MATERIALS AND METHODS: In this retrospective cross-sectional descriptive study, maxillofacial CBCT scan data were obtained from 40 adults. The 3D images were evaluated in five axial sections at 2, 4, 6, 8 and 10 mm from the cementoenamel Junction (CEJ). To determine inter-radicular spaces, tangent lines were drawn buccolingually to the roots in axial section and the minimum distance between these two lines was measured. The data was analysed using Friedman test with SPSS(ver.13). RESULTS: Interradicular spaces of canine to second molar increased from cervical to apical direction. The maximum distance was recorded at 4 mm from the CEJ between first and second molars. CONCLUSION: According to our findings there is a distinct pattern of inter-radicular space changes in mandible. Attention to this pattern during placement of mini-implants can ensure the safety of the procedure.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
سید حسین مسلم زادهاول
آیدین سهرابیدوم
علی رفیقیسوم
امین نوری زادهپنجم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
JCDR article.pdf1396/05/18207714دانلود