Extraction of ammonia and nitrite using modified magnetite iron oxide nanoparticles before spectrophotometric determination in different water samples

Extraction of ammonia and nitrite using modified magnetite iron oxide nanoparticles before spectrophotometric determination in different water samples


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: احد باویلی تبریزی

کلمات کلیدی: ammonia; environmental water samples; nitrite; MSPE; spectrophotometry

نشریه: 15130 , 9 , 95 , 2015

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله احد باویلی تبریزی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات بیوتکنولوژی(زیست فناوری)
کد مقاله 60574
عنوان فارسی مقاله Extraction of ammonia and nitrite using modified magnetite iron oxide nanoparticles before spectrophotometric determination in different water samples
عنوان لاتین مقاله Extraction of ammonia and nitrite using modified magnetite iron oxide nanoparticles before spectrophotometric determination in different water samples
ناشر 2
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت http://dx.doi.org/10.1080/03067319.2015.1058933

خلاصه مقاله
hide/show

A new analytical approach was developed for the extraction and determination of ammonia and nitrite in environmental water samples involving magnetic solid-phase extraction (MSPE) with magnetite nanoparticles (MNPs) as the adsorbent. The procedure is based on the derivatisation of ammonia based on Berthelot reaction. The obtained indophenol dye was extracted using MSPE and determined spectrophotometrically at 655 ± 3 nm. Nitrite ion is determined after its reduction to ammonia in the presence of Zn/HCl. The main factors that affected the extraction efficiency were studied and optimised. The method gave calibration curves for ammonia with good linearity in the range 10–550 μg L−1, and correlation coefficients (r) higher than 0.99. The detection and quantification limit was found to be 3.1 and 10.2 μg L−1, respectively. The method showed good precision and accuracy, with intraand inter-assay precisions of less than 6.6% at all concentrations. The recoveries ranged 89– 105% and 88–105%, for ammonia and nitrite determination, respectively. The method was applied to the determination of the target analytes in real samples.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
احد باویلی تبریزیاول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
ammonia & nitrite IJEAC.pdf1396/02/06311012دانلود