Applying cloud point extraction technique for the extraction of oxazepam from human urine as a colour or fluorescent derivative prior to spectroscopic analysis methods

Applying cloud point extraction technique for the extraction of oxazepam from human urine as a colour or fluorescent derivative prior to spectroscopic analysis methods


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: احد باویلی تبریزی

کلمات کلیدی: oxazepam determination; cloud point extraction; spectrophotometry; spectrofluorimetry; urine

نشریه: 9637 , - , 4 , 2012

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله احد باویلی تبریزی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده داروسازی
کد مقاله 60567
عنوان فارسی مقاله Applying cloud point extraction technique for the extraction of oxazepam from human urine as a colour or fluorescent derivative prior to spectroscopic analysis methods
عنوان لاتین مقاله Applying cloud point extraction technique for the extraction of oxazepam from human urine as a colour or fluorescent derivative prior to spectroscopic analysis methods
ناشر 2
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت https://www.researchgate.net/profile/Ahad_Bavili-Tabrizi/publication/50291767_Applying_cloud_point_extraction_technique_for_the_

خلاصه مقاله
hide/show

Two new methods based on cloud point extraction (CPE) technique were developed and optimized for the extraction and preconcentration of oxazepam from human urine, as an azo or fluorescent derivative. The first method is a spectrophotometric one, which is based on the acid hydrolysis of the oxazepam to a benzophenone, diazotization of the benzophenone, and then the coupling with oxine to form an azo dye. The second method is a spectrofluorimetric one, which involves reduction of the target compound using Zn◦/HCl at room temperature with the formation of a highly fluorescent derivative. The main factors affecting the chemical reactions and CPE were investigated and optimized systematically. Under optimum experimental conditions, the calibration graphs were linear in the range of 0.1 to 1.5 (0.05 to 2.0) μg/ml with correlation coefficients of 0.9989 (0.9985), for the CPE-spectrophotometric (CPE-spectrofluorimetric) method. The limit of detectionwas found to be 0.034 (0.018) μg/ml and the relative standard deviation was calculated to be 1.35 (2.52)%. Recoveries in the spiked samples ranged from 87 to 94%. Finally, the proposed methods were applied to the determination of oxazepam in human urine.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
احد باویلی تبریزیاول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
OXZ-dta.pdf1396/02/06172702دانلود