Development of a dispersive liquid–liquid microextraction method for iron speciation and determination in different water samples

Development of a dispersive liquid–liquid microextraction method for iron speciation and determination in different water samples


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: احد باویلی تبریزی

کلمات کلیدی: Iron Dispersive liquid–liquid microextraction Spectrophotometry Water Parenteral solution

نشریه: 20359 , - , 183 , 2010

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله احد باویلی تبریزی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده داروسازی
کد مقاله 60564
عنوان فارسی مقاله Development of a dispersive liquid–liquid microextraction method for iron speciation and determination in different water samples
عنوان لاتین مقاله Development of a dispersive liquid–liquid microextraction method for iron speciation and determination in different water samples
ناشر 1
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت journal homepage: www.elsevier.com/locate/jhazmat

خلاصه مقاله
hide/show

A novel, simple and efficient method for the iron (Fe) speciation and determination in different water samples was developed using dispersive liquid–liquid microextraction (DLLME) technique followed by spectrophotometric analysis. The procedure is based on complexation of Fe(II) with O-phenanthroline (O-Phen), the subsequent ion-association formation with picrate anion, then extraction of the complex using DLLME technique. Some important parameters such as the type and volume of extraction and dispersive solvents as well as the extraction time were investigated and optimized in detail. Under the optimum conditions, the calibration graphs were linear over the range of 0.025–1.0gmL−1 with limit of detection of 7.5gL−1. Relative standard deviation for five replicate determinations of Fe at 0.2gmL−1 concentration level was calculated to be 1.2%. Average recoveries for spiked samples were determined to be between 90% and 108%. The method was applied to water samples and parenteral solutions and the amounts of Fe found in these samples using the proposed method were similar with those obtained by a standard method.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
احد باویلی تبریزیاول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Fe (J Haz Mater).pdf1396/02/06221460دانلود