Electrochemical sensing of doxorubicin in unprocessed whole blood, cell lysate, and human plasma samples using thin film of poly-arginine modified glassy carbon electrode

Electrochemical sensing of doxorubicin in unprocessed whole blood, cell lysate, and human plasma samples using thin film of poly-arginine modified glassy carbon electrode


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: محمد حسن زاده محله , جعفر سلیمانی , مرتضی اسکندانی , مریم خوب نسب جعفری , ابوالقاسم جویبان

کلمات کلیدی: Doxorubicin; Electrochemistry; Biological fluids; Poly-amino acid; Whole blood; Cell lysate

نشریه: 23407 , 01 , 77 , 2017

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محمد حسن زاده محله
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات کاربردی دارویی
کد مقاله 60448
عنوان فارسی مقاله Electrochemical sensing of doxorubicin in unprocessed whole blood, cell lysate, and human plasma samples using thin film of poly-arginine modified glassy carbon electrode
عنوان لاتین مقاله Electrochemical sensing of doxorubicin in unprocessed whole blood, cell lysate, and human plasma samples using thin film of poly-arginine modified glassy carbon electrode
ناشر 6
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق) Materials Science and Engineering: C
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت http://www.sciencedirect.com/science/article/pii/S0928493116324080

خلاصه مقاله
hide/show

A thin film of poly-arginine fabricated on glassy carbon electrode by one step electrodeposition method is applied for detection of doxorubicin hydrochloride in whole blood, cell lysate, and untreated-plasma samples. Cyclic voltammetry results indicated that the doxorubicin is oxidized via two electrons and two protons at physiological pH (pH = 7.4) using poly-arginine thin film modified glassy carbon. More importantly, electrostatic repulsion takes place between the prepared polymer film-modified electrode and selected drug resulting in the signal amplification on oxidation of doxorubicin and lowering its over potential and thereby selective detection of doxorubicin in real samples. The apparent electron transfer rate constant and transfer coefficient were determined by cyclic voltammetry and were approximately 10.1 s− 1 and 0.82, respectively. Also, using differential-pulse voltammetric technique for sensitive detection of doxorubicin in whole blood and plasma samples, the lower limit of quantification was 69 nM and 103 nM, respectively. Also, application of this amino acid based biocompatible polymeric electrode was tested to the determination of doxorubicin in unprocessed whole blood and the results show that this sensor could be applied in online and real time monitoring of this anti-cancer drug in real samples which is important for clinical research.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
محمد حسن زاده محلهدوم
جعفر سلیمانیاول
مرتضی اسکندانیسوم
مریم خوب نسب جعفریچهارم
ابوالقاسم جویبانششم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
111.pdf1396/01/202816758دانلود