THE COMPARISON OF DIMENSIONAL ACCURACY OF MODIFIED TWO-STAGE PUTTY-WASH CONDENSATION S POLYVINYL MOLDING METHOD AND DISTANCE TWO-STAGE PUTTY-WASH MOLDING METHOD

THE COMPARISON OF DIMENSIONAL ACCURACY OF MODIFIED TWO-STAGE PUTTY-WASH CONDENSATION S POLYVINYL MOLDING METHOD AND DISTANCE TWO-STAGE PUTTY-WASH MOLDING METHOD


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: حسین اسلامی , علیرضا پورنصرالله , رامین نگاهداری , پریسا فلسفی , وحید فخرزاده

کلمات کلیدی: Keywords: putty-wash technique, prosthodontics, molding technique

نشریه: 55239 , 4 , 9 , 2016

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله حسین اسلامی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 59838
عنوان فارسی مقاله THE COMPARISON OF DIMENSIONAL ACCURACY OF MODIFIED TWO-STAGE PUTTY-WASH CONDENSATION S POLYVINYL MOLDING METHOD AND DISTANCE TWO-STAGE PUTTY-WASH MOLDING METHOD
عنوان لاتین مقاله THE COMPARISON OF DIMENSIONAL ACCURACY OF MODIFIED TWO-STAGE PUTTY-WASH CONDENSATION S POLYVINYL MOLDING METHOD AND DISTANCE TWO-STAGE PUTTY-WASH MOLDING METHOD
ناشر 6
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح سه – Scopus
آدرس لینک مقاله/ همایش در شبکه اینترنت https://www.novapublishers.com/catalog/product_info.php?products_id=6349

خلاصه مقاله
hide/show

Background and Aims: Impression in Fixed Prosthodontics is very important. An impression technique is one of the most important factors affecting the dimensional changes of die. Recent studies showed the conflicting results about the impression techniques. This study was carried out with aim of comparison two impression techniques of modified two-step putty-wash impression technique with two-step putty-wash technique with spacing. Materials and Methods: This experimental study was done on a laboratory model. 10 impression of laboratory model were taken for each technique of modifided two-step polyvinylsiloxane putty-wash impression technique and two-step putty-wash technique with spacing. Impression was poured after 30 minute with vel-mix plaster. Die’s height, diameter and distance between dies were measured 6 times in laboratory model and 3 times in stone models by an expert who was not aware of impression techniques by digital coulis. Size plaster sample comparing with experimental model and result were tested by ANOVA and t-test analysis (p < 0.05 was considered significant). Results: Based on the result, there was no significant difference between two techniques in height and distance between two dies and modified impression techniques more accurate and closer to the original model. But in die’s diameter there was significant difference between two techniques.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
حسین اسلامیدوم
علیرضا پورنصراللهسوم
رامین نگاهداریچهارم
پریسا فلسفیپنجم
وحید فخرزادهاول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
DIMENSIONAL ACCURACY.pdf1395/10/25135304دانلود