Er,Cr:YSGG Laser as a Novel Method for Rebonding Failed Ceramic Brackets

Er,Cr:YSGG Laser as a Novel Method for Rebonding Failed Ceramic Brackets


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: آیدین سهرابی , سودابه کیمیائی , سهند ریخته گران , ساناز جعفری

کلمات کلیدی:

نشریه: 27353 , 12 , 34 , 2016

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله آیدین سهرابی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 59762
عنوان فارسی مقاله Er,Cr:YSGG Laser as a Novel Method for Rebonding Failed Ceramic Brackets
عنوان لاتین مقاله Er,Cr:YSGG Laser as a Novel Method for Rebonding Failed Ceramic Brackets
ناشر 4
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت http://online.liebertpub.com/doi/abs/10.1089/pho.2014.3868

خلاصه مقاله
hide/show

Objective: Since there is no standard method for rebonding loose ceramic brackets, the aim of this study was to evaluate the possibility of using Er,Cr:YSGG laser to eliminate the remaining composite materials from the base of ceramic brackets and to compare the bond strength of rebonded brackets with the new ones. Materials and methods: Sixty-two extracted human premolars were mounted in acrylic cylinders. Thirty-one ceramic brackets were bonded, and shear bond strength was tested using Hounsfield testing machine. The remnants of the bonding material were removed from the bases of brackets using Er,Cr:YSGG laser. These brackets were rebonded to 31 fresh teeth and again shear bond strength was measured. Pattern of debonding was assessed in both cases under a stereomicroscope and graded according to ARI index. Data were analyzed with independent t-test and Fisher’s exact test. Results: Mean shear bond strength of the bond and rebond groups was 12.29 – 5.46 and 10.58 – 5.16 MPa, respectively. There were no significant differences between the two groups ( p = 0.21). Pattern of bond failure was not statistically different between the two groups. Conclusions: Er,Cr:YSGG laser was effective in removing the remnants of bonding material from the base of ceramic brackets without any interference with the ceramic base itself, demonstrating that it might be a suitable method for rebonding ceramic brackets.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
آیدین سهرابیاول
سودابه کیمیائیسوم
سهند ریخته گرانچهارم
ساناز جعفریدوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
2016 Sanaz Jafari Cermaic Er-CrYSGG Laser as a Novel M-2880.pdf1396/02/18165895دانلود